Model V-max
(Vdc)
I-max
(A)
I-hold
(A)
I-trip
(A)
Agency Approval Spec
HPD1410 20
100 14.10 26.20RoHS
HPD190S 15
100 1.90 3.90UL/TUV/RoHS
HPD260S 15
100 2.60 5.80UL/TUV/RoHS
HPD380 15
100 3.80 8.30UL/TUV/RoHS
HPD450 20
100 4.50 8.90UL/TUV/RoHS
HPD550 20
100 5.50 10.50UL/TUV/RoHS
HPD600 20
100 6.00 11.70UL/TUV/RoHS
HPD730 20
100 7.30 14.10UL/TUV/RoHS
HPD730X 20
100 7.30 14.10UL/TUV/RoHS
HPD900 20
100 9.00 16.70RoHS
MHD120S 15
100 1.20 2.70UL/TUV/RoHS
MHD175S 15
100 1.75 3.80UL/TUV/RoHS
MHD200 24
100 2.00 4.40UL/TUV/RoHS
MHD350 24
100 3.50 6.30UL/TUV/RoHS
MHD420 24
100 4.20 7.60UL/TUV/RoHS
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25°C still air.
ItRip = Trip Current:minimum current at which the device will trip in 25°C still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).
[ 1 ] 2
Copyright(C) 2010 ALPHA-TOP,INC All rights are reserved by CHECK-E Tech Corp.