Model V-max
(Vdc)
I-max
(A)
I-hold
(A)
I-trip
(A)
Agency Approval Spec
R16-090 16
100 0.90 1.80RoHS
R16-1000 16
100 10.00 17.00UL/RoHS
R16-110 16
100 1.10 2.20RoHS
R16-1100 16
100 11.00 18.70UL/RoHS
R16-1200 16
100 12.00 20.40UL/RoHS
R16-135 16
100 1.35 2.70RoHS
R16-1400 16
100 14.00 23.80UL/RoHS
R16-160 16
100 1.60 3.20RoHS
R16-185 16
100 1.85 3.70RoHS
R16-250 16
100 2.50 5.00RoHS
R16-300 16
100 3.00 5.10RoHS
R16-400 16
100 4.00 8.00RoHS
R16-500 16
100 5.00 8.50UL/RoHS
R16-600 16
100 6.00 10.20UL/RoHS
R16-700 16
100 7.00 11.90UL/RoHS
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25°C still air.
ItRip = Trip Current:minimum current at which the device will trip in 25°C still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).
[ 1 ] 2 3 4
Copyright(C) 2010 ALPHA-TOP,INC All rights are reserved by CHECK-E Tech Corp.