Model V-max
(Vdc)
I-max
(A)
I-hold
(A)
I-trip
(A)
Agency Approval Spec
mSMD010 30
100 0.10 0.30RoHS/UL/TUV
mSMD010-60V 60
100 0.10 0.30RoHS/UL/TUV
mSMD014 60
100 0.14 0.34RoHS/UL/TUV
mSMD020 30
100 0.20 0.40RoHS/UL/TUV
mSMD020-60V 60
100 0.20 0.40RoHS/UL/TUV
mSMD030 30
100 0.30 0.60RoHS/UL/TUV
mSMD030-60V 60
100 0.30 0.60RoHS/TUV
mSMD035 30
100 0.35 0.70RoHS/UL/TUV
mSMD035-60V 60
100 0.35 0.700.70
mSMD050 33
100 0.50 1.00RoHS/UL/TUV
mSMD050-15V 15
100 0.50 1.00RoHS/UL/TUV
mSMD050-60V 60
100 0.50 1.00RoHS/UL/TUV
mSMD075 13.2
40 0.75 1.5RoHS/UL/TUV
mSMD075-16V 16
100 0.75 1.5RoHS/TUV
mSMD075-24V 24
100 0.75 1.50RoHS/UL/TUV
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25°C still air.
ItRip = Trip Current:minimum current at which the device will trip in 25°C still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).
[ 1 ] 2 3 4 5 6 7 8 9 10 11
Copyright(C) 2010 ALPHA-TOP,INC All rights are reserved by CHECK-E Tech Corp.