Model V-max
(Vdc)
I-max
(A)
I-hold
(A)
I-trip
(A)
Agency Approval Spec
nSMD003 60
100 0.03 0.10RoHS
nSMD005 60
100 0.05 0.15UL/RoHS
nSMD010 60.0
100 0.10 0.25UL/RoHS
nSMD012 60.0
100 0.12 0.29UL/RoHS
nSMD016-30V 30
100 0.16 0.37RoHS
nSMD020 24
100 0.20 0.46UL/RoHS
nSMD020-30V 30
100 0.20 0.46RoHS
nSMD025 16.0
100 0.25 0.50UL/RoHS
nSMD025-24V 24
100 0.25 0.50RoHS
nSMD025-30V 30
100 0.25 0.50RoHS
nSMD035 6.0
100 0.35 0.75UL/RoHS
nSMD035-13.2V 13.2
100 0.35 0.75RoHS
nSMD035-16V 16
100 0.35 0.75UL/RoHS
nSMD035-24V 24
100 0.35 0.75RoHS
nSMD035-33V 33
100 0.35 0.75RoHS
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25°C still air.
ItRip = Trip Current:minimum current at which the device will trip in 25°C still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).
[ 1 ] 2 3