Model V-max
(Vdc)
I-max
(A)
I-hold
(A)
I-trip
(A)
Agency Approval Spec
SL1210300-16V 16
50 3.00 6.00UL/RoHS
SL1210350 6
50 3.50 7.00UL/RoHS
SL1210350-16V 16
50 3.50 7.00UL/RoHS
SL1210380 6
50 3.80 7.60UL/RoHS
SL1210380-16V 16
50 3.80 7.60UL/RoHS
SL1210400 6
50 4.00 8.00UL/RoHS
SL1210400-16V 16
50 4.00 8.00UL/RoHS
SL1210400-8V 8
50 4.00 8.00UL/RoHS
SL1210450 6
50 4.50 9.00UL/RoHS
SL1210450-16V 16
50 4.50 9.00UL/RoHS
SL1210500 6
50 5.00 10.00UL/RoHS
SL1210500-16V 16
50 5.00 10.00UL/RoHS
SL1210550 6
50 5.50 11.00UL/RoHS
SL1210550-16V 16
50 5.50 11.00UL/RoHS
SL1210600 6
50 6.00 12.00UL/RoHS
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25°C still air.
ItRip = Trip Current:minimum current at which the device will trip in 25°C still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).