Model V-max
(Vdc)
I-max
(A)
I-hold
(A)
I-trip
(A)
Agency Approval Spec
SMD0805-025 9
100 0.25 0.55RoHS
SMD0805-025-13.2V 13.2
100 0.25 0.55RoHS
SMD0805-035 6
100 0.35 0.75UL/RoHS
SMD0805-035-13.2V 13.2
100 0.35 0.75RoHS
SMD0805-035-16V 16
100 0.35 0.75RoHS
SMD0805-050 6
100 0.50 1.00UL/RoHS
SMD0805-050-12V 12
100 0.50 1.00UL/RoHS
SMD0805-050-13.2V 13.2
100 0.50 1.00UL/RoHS
SMD0805-050-16V 16
100 0.50 1.00UL/RoHS
SMD0805-075 6
40 0.75 1.50UL/RoHS
SMD0805-100 6
100 1.00 1.95UL/TUV/RoHS
SMD0805-110 6
100 1.10 2.20UL/RoHS
SMD0805-125 6
100 1.25 2.50UL/RoHS
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25°C still air.
ItRip = Trip Current:minimum current at which the device will trip in 25°C still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).