Model V-max
(Vdc)
I-max
(A)
I-hold
(A)
I-trip
(A)
Agency Approval Spec
SL1812270-12V 12
50 2.70 6.20RoHS
SL1812300 6
50 3.00 7.00RoHS
SL1812300-12V 12
50 3.00 7.00RoHS
SL1812350 6
50 3.50 7.00RoHS
SL1812350-12V 12
50 3.50 7.00RoHS
SL1812370 6
50 3.70 7.50RoHS
SL1812370-12V 12
50 3.70 7.50RoHS
SL1812400 6
50 4.00 8.00RoHS
SL1812400-12V 12
50 4.00 8.00RoHS
SL1812450 6
50 4.50 9.00RoHS
SL1812450-12V 12
50 4.50 9.00RoHS
SL1812500 6
50 5.00 10.00RoHS/UL
SL1812500-12V 12
50 5.00 10.00RoHS/UL
SL1812500-16V 16
50 5.00 10.00RoHS/UL
SL1812500-8V 8
50 5.00 10.00RoHS/UL
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25°C still air.
ItRip = Trip Current:minimum current at which the device will trip in 25°C still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).
1 2 3 4 5 6 7 8 9 10 11 12 13 [ 14 ] 15 »