Model V-max
(Vdc)
I-max
(A)
I-hold
(A)
I-trip
(A)
Agency Approval Spec
SMD0805-075 6
40 0.75 1.50UL/RoHS
SMD0805-100 6
100 1.00 1.95UL/TUV/RoHS
SMD0805-110 6
100 1.10 2.20UL/RoHS
SMD0805-125 6
100 1.25 2.50UL/RoHS
SMD100L 33
100 1.10 2.20RoHS/UL
SMD1210-005 30
100 0.05 0.15RoHS
SMD1210-010 30
100 0.10 0.30RoHS/UL
SMD1210-010-60V 60
100 0.1 0.30UL/RoHS
SMD1210-020 30
100 0.20 0.40RoHS
SMD1210-035 6
100 0.35 0.75UL/RoHS
SMD1210-050 13.2
100 0.50 1.00UL/RoHS
SMD1210-075 6
100 0.75 1.50UL/RoHS
SMD1210-110 6
100 1.10 2.20UL/RoHS
SMD1210-150 6
100 1.50 3.00UL/RoHS
SMD125L 33
100 1.25 2.50RoHS
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25°C still air.
ItRip = Trip Current:minimum current at which the device will trip in 25°C still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).
« 16 17 18 19 20 21 22 23 24 25 26 [ 27 ] 28 29
Copyright(C) 2010 ALPHA-TOP,INC All rights are reserved by CHECK-E Tech Corp.